My Georgia Plumber is a trusted plumbing service company that has been serving the Lithonia, GA area for over 30 years. We offer a wide range of residential and commercial plumbing services, including drain cleaning and repair, sewer line and water line services, water heater services, gas lines, bathroom, kitchen and laundry plumbing and remodeling services. We are dedicated to providing our Lithonia customers with the highest quality of service possible, and we believe that our experience and reputation speak for themselves. If you are in need of a plumber, please give us a call today!
Local Reviews
for Lithonia, GA

Trevor J.
Customer States: There is a leak under the kitchen sink. Hallway bathroom and guest bathroom tubs drain slow. Technician Notes: Out today to look into issue with a leak under the kithen sink. Found a loose tubular drain nut. Tightened nut and this solved the issue at hand. However, the tubular under the kitchen sink was not ran properly. The trap adapter is higher than the tubular. And this can cause drainage issues. Guest bathroom tub and hallway bathroom tub both had hair in them. Cleared hair from drain and tested for proper flow. Resolution: Built estimate to rework kitchen drain. It does function, but is not proper. Job Notes: Send estimate to ResiPro. I do not have all parts needed to perform this task. May need to open back of cabinet up to gain access to pipe. Job Status: Complete. Autho: Bill to ResiPro. Estimates: Good to send.

Trevor J.
Customer States: The water in the hallway bathroom upstairs shower will not shut off. They turned the water off to the home to keep water from flowing continuously. Technician Notes: Found that the water in the upstairs hallway bathroom is constantly flowing on the cold side in the shower. Three handle valve. Removed stem from valve to discover the washer and screw came off of the stem. Resolution: Installed a new washer and tightened screw back to stem. Reinstalled stem in the three handle valve. Restored water and tested for proper function. Job Notes: No exterior sewer clean out located while onsite. Bill to ResiPro. Job Status: Complete. Autho: Bill to ResiPro. Estimates: No additional needed.
d.casto@mygeorgiaplumber.com
Customer stated: powder bathroom toilet is clogged. Technician notes: used closet auger to clear blockage in powder bath toilet. Retried piece of metal wire from toilet. All performing as it should at this time. Mpg notes: please bill accordingly Job status: complete Estimates: no further needed

James T.
The tenants just moved in and the gas company came out to turn everything on and found a leak from the t&p valve We found a drip from the threads of the t&p valve and the cpvc We checked the water pressure and found that it is extremely high it pegged out my gauge Upon further inspection the t&p appears to have been replaced once before The water heater is only 2 years old We replaced the prv and we replaced the t&p valve on the water Everything tested with no issues Job completed No other estimates are needed No visible clean out
d.casto@mygeorgiaplumber.com
TECHNICIAN NOTES: drained, disconnected and removed existing leaking water heater located in basement bathroom closet, installed new 50 gallon electric water heater and all code required items. RESOLUTION/RECOMMENDATIONS: turned all water and power back on to house, all is working properly at this time. JOB STATUS: COMPLETE ESTIMATES: (READY TO SEND OR NEED REVIEW) This is a choice estimate to replace the existing 50 gallon electric water heater and all code required items located in the basement bathroom closet, this will be a two man job due to the location of the heater.

James T.
CUSTOMER STATED: The tenants complaint is that the water pressure coming out of the master bathroom shower head is to weak TECHNICIAN NOTES: We tested the shower and we noticed a slight pressure drop in the water coming out of the shower head We the removed the shower head and found the amount of water coming out of the tub spout and the shower head is drastically different We went into the crawl space and found the area under the tub and there is no active leak coming from the shower valve or from the shower head line There is evidence of past leaks There is pressure with the shower head even with the low amount of flow From what I can tell the diverter is opening all the way RESOLUTION/RECOMMENDATIONS: We pulled the diverter stem and found that the screw for the flat washer was loose the stem looks to be fairly new and the flat washer was good We tightened the screw and reinstalled the stem Tested with no issues If any more problems happen then I’d recommend replacing th
preston.boyd@mygeorgiaplumber.com
CUSTOMER STATED: Water heater is making weird noises. TECHNICIAN NOTES: Out to the residence today for the concern of a water heater making loud noises. When I arrived the homeowner showed me a video of the temperature and pressure relief valve making a loud banging noise. Existing 50 gallon electric water heater is 15 years of age. While on site, i had hot water running for 20 minutes but it would not make any mechanical failures. Water pressure reading was 100 PSI. I have recommended to the homeowner that she can submit a new claim for the prv to her warranty RESOLUTION/RECOMMENDATIONS: No mechanical failures found while on site today. I have recommended to the homeowner to consider replacing the hot water system due to the age of the existing electric water heater. JOB NOTES: JOB STATUS: COMPLETE/NOTCOMPLETE (RETURN TRIP NEEDED?) Job complete. Please send.
d.casto@mygeorgiaplumber.com
CUSTOMER STATED: water heater leaking TECHNICIAN NOTES: upon inspection found a electric 50 gallon ruud water heater that is 16 years old located in the basement bathroom closet. The water heater has an internal leak on the top of the tank, the entire heater is severely rusted and replacement is recommended. **house has no working hose bibs** RESOLUTION/RECOMMENDATIONS: water heater will need to be replaced. JOB STATUS: not complete, awaiting approval PARTS: 50 gallon electric heater will be needed AUTHO: submitted online ESTIMATES: customer did not want a service estimate, would like to wait for choice.

Santos Q.
- A part needs to be ordered for the 3-handle Kohler shower valve as the pressure is at 90. - The pressure regulator valve could not be found, so we will need to dig up the area at the meter and install the pressure regulator valve there.
preston.boyd@mygeorgiaplumber.com
CUSTOMER STATED : Tub/shower is leaking TECHNICIAN NOTES : Out to the residence today for the concern of a leaking tub/shower. When I arrived I found a constant drip coming from the tub spout. Tub spout is constantly dripping due to a defective delta shower cartridge. While on site we have also found a failed pressure regulating valve. RESOLUTION : Replaced existing defective delta shower cartridge and defective pressure regulating valve located in the garage under the existing water heater. Water pressure is now 45 PSI after replacing defective prv. After making repairs, we have fully pressurized the system to properly test for leaks or concerns. There are no further concerns at this point in time. Job complete. Please bill resipro for invoice amount.